-- $Id: yamaha-rt-switch.mib.txt,v 1.8 2023/06/26 17:17:00 homori Exp $

YAMAHA-RT-SWITCH DEFINITIONS ::= BEGIN

IMPORTS
	mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks
		FROM RFC1155-SMI
	OBJECT-TYPE
		FROM RFC-1212
	DisplayString, PhysAddress
		FROM SNMPv2-TC
	TRAP-TYPE
		FROM RFC-1215
	yamahaRTSwitch
		FROM YAMAHA-RT;

-- Information of controlled switch

yrSwNumber OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The number of controlled switch on this system."
	::= { yamahaRTSwitch 1 }

yrSwTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF YrSwEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A list of controlled switch entries."
	::= { yamahaRTSwitch 2 }

yrSwLoopDetect 
	OBJECT IDENTIFIER
	::= { yamahaRTSwitch 3 }

yrSwPoE 
	OBJECT IDENTIFIER
	::= { yamahaRTSwitch 4 }

yrSwEntry OBJECT-TYPE
	SYNTAX	YrSwEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A controlled switch entry."
	INDEX	{ yrSwIndex }
	::= { yrSwTable 1 }

YrSwEntry ::=
	SEQUENCE {
		yrSwIndex
			INTEGER,
		yrSwProduct
			INTEGER,
		yrSwName
			DisplayString,
		yrSwFirmwareRevision
			DisplayString,
		yrSwPhysAddress
			DisplayString,
		yrSwPortNumber
			INTEGER,
		yrSwFanStatus
			INTEGER,
		yrSwSupply
			INTEGER,
		yrSwTemp
			INTEGER,
		yrSwPowerFailure
			INTEGER
	}

yrSwIndex OBJECT-TYPE
	SYNTAX	INTEGER (1..2147483647)
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each controlled switch."
	::= { yrSwEntry 1 }

yrSwProduct OBJECT-TYPE
	SYNTAX	INTEGER { swxgeneric(1), swx2200-8g(2), swx2200-24g(3), swx2200-8poe(4), swx2100-8g(5), swx2100-16g(6), swx2100-24g(7), swx2100-5poe(8), swx2100-10poe(9), swr2100p-5g(10), swr2100p-10g(11) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The product number."
	::= { yrSwEntry 2 }

yrSwName OBJECT-TYPE
	SYNTAX	DisplayString
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The controlled switch's 'system-name'."
	::= { yrSwEntry 3 }

yrSwFirmwareRevision OBJECT-TYPE
	SYNTAX	DisplayString
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A textual string containing a revision information of
		an firmware."
	::= { yrSwEntry 4 }

yrSwPhysAddress OBJECT-TYPE
	SYNTAX	DisplayString
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The controlled switch's MAC Address"
	::= { yrSwEntry 5 }

yrSwPortNumber OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The number of controlled switch's ports."
	::= { yrSwEntry 6 }

yrSwFanStatus OBJECT-TYPE
	SYNTAX	INTEGER { normal(1), lock(2), none(3) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The status of controlled switch's fan."
	::= { yrSwEntry 7 }

yrSwSupply OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The supplied  value of controlled switch's power unit."
	::= { yrSwEntry 8 }

yrSwTemp OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The controlled switch's temperature."
	::= { yrSwEntry 9 }

yrSwPowerFailure OBJECT-TYPE
	SYNTAX	INTEGER { normal(1), failure(2) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The status of controlled switch's power unit."
	::= { yrSwEntry 10 }

yrSwLoopDetectPortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF YrSwLoopDetectPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A list of controlled switch's loop-detect port entries."
	::= { yrSwLoopDetect 1 }

yrSwLoopDetectPortEntry OBJECT-TYPE
	SYNTAX	YrSwLoopDetectPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A controlled switch's loop-detect port entries."
	INDEX	{ yrSwIndex, yrSwLoopDetectPortIndex }
	::= { yrSwLoopDetectPortTable 1 }

YrSwLoopDetectPortEntry ::=
	SEQUENCE {
		yrSwLoopDetectPortIndex
			INTEGER,
		yrSwLoopDetectPortUse
			INTEGER,
		yrSwLoopDetectPortStatus
			INTEGER
	}

yrSwLoopDetectPortIndex OBJECT-TYPE
	SYNTAX	INTEGER (1..2147483647)
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each controlled switch's port."
	::= { yrSwLoopDetectPortEntry 1 }

yrSwLoopDetectPortUse OBJECT-TYPE
	SYNTAX	INTEGER { enabled(1), disabled(2) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The desired state of each controlled switch's loop-detect port."
	::= { yrSwLoopDetectPortEntry 2 }

yrSwLoopDetectPortStatus OBJECT-TYPE
	SYNTAX	INTEGER { normal(1), loopdetect(2), linkdown(3) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The current operational state of each controlled switch's loop-detect port."
	::= { yrSwLoopDetectPortEntry 3 }

yrSwPoEPortTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF YrSwPoEPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A list of controlled switch's PoE port entries."
	::= { yrSwPoE 1 }

yrSwPoEPortEntry OBJECT-TYPE
	SYNTAX	YrSwPoEPortEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A controlled switch's PoE port entries."
	INDEX	{ yrSwIndex, yrSwPoEPortIndex }
	::= { yrSwPoEPortTable 1 }

YrSwPoEPortEntry ::=
	SEQUENCE {
		yrSwPoEPortIndex
			INTEGER,
		yrSwPoEPortSetting
			INTEGER,
		yrSwPoEPortDetectClass
			INTEGER,
		yrSwPoEPortState
			INTEGER,
		yrSwPoEPortSupply
			INTEGER
	}

yrSwPoEPortIndex OBJECT-TYPE
	SYNTAX	INTEGER (1..2147483647)
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each controlled switch's port."
	::= { yrSwPoEPortEntry 1 }

yrSwPoEPortSetting OBJECT-TYPE
	SYNTAX	INTEGER { class3(3), class4(4) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The set of each controlled switch's PoE port."
	::= { yrSwPoEPortEntry 2 }

yrSwPoEPortDetectClass OBJECT-TYPE
	SYNTAX	INTEGER { class0(1), class1(2), class2(3), class3(4), class4(5) }
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The recogmized class of each controlled switch's PoE port."
	::= { yrSwPoEPortEntry 3 }

yrSwPoEPortState OBJECT-TYPE
	SYNTAX	INTEGER {
		supply-class0(1),
		supply-class1(2),
		supply-class2(3),
		supply-class3(4),
		supply-class4(5),
		terminate(6),
		overcurrent(7),
		forced-terminate(8),
		over-supply(9),
		over-temp(10),
		fanlock(11),
		power-failure(12),
		class-failure(13),
		over-guardband(14)
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The current state of each controlled switch's PoE port."
	::= { yrSwPoEPortEntry 4 }

yrSwPoEPortSupply OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The power supplied value of each controlled switch's PoE port."
	::= { yrSwPoEPortEntry 5 }

-- Traps

yrSwFindSwitch TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwNumber, yrSwProduct, yrSwPhysAddress }
	DESCRIPTION
		"This trap signifies that a controlled switch is detected."
	::= 1

yrSwDetectDown TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwNumber, yrSwProduct, yrSwPhysAddress }
	DESCRIPTION
		"This trap signifies that a controlled switch is lost."
	::= 2

yrSwFanLock TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwFanStatus }
	DESCRIPTION
		"This trap signifies that a controlled switch's fan lock."
	::= 3

yrSwOverSupply TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwSupply }
	DESCRIPTION
		"This trap signifies that a controlled switch's PoE over supply."
	::= 4

yrSwOverTemp TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwTemp }
	DESCRIPTION
		"This trap signifies that a controlled switch's over temperature."
	::= 5

yrSwPowerUnitFailure TRAP-TYPE
	ENTERPRISE	yamahaRTSwitch
	VARIABLES	{ yrSwPowerFailure }
	DESCRIPTION
		"This trap signifies that a controlled switch's Power unit failure."
	::= 6

yrSwLoopDetectPort TRAP-TYPE
	ENTERPRISE	yrSwLoopDetect
	VARIABLES	{ yrSwLoopDetectPortStatus }
	DESCRIPTION
		"This trap signifies that a controlled switch's port is loop-detect."
	::= 1

yrSwPoESupplyPort TRAP-TYPE
	ENTERPRISE	yrSwPoE
	VARIABLES	{ yrSwPoEPortState }
	DESCRIPTION
		"This trap signifies that a controlled switch's port is PoE supply."
	::= 1

yrSwPoETerminatePort TRAP-TYPE
	ENTERPRISE	yrSwPoE
	VARIABLES	{ yrSwPoEPortState }
	DESCRIPTION
		"This trap signifies that a controlled switch's port is PoE terminate."
	::= 2
END