--*    SAGEM, IONOS 											    *
--*******************************************************************
--*******************************************************************
--
--  Filename: equip
--
--  File type: .mib    
-- 
--  Description:	SNMP source Mib file.
--
--			Contains general description and operation for
--			equipent level.
--             
--
--  Version:  19 11 2002
--	
--  Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS 
--     
--  Contact: D. Mobuchon, F. Bonnevialle
--
--  History: 
--		Version: 			Date: 04 08 98
--		Version: MIB-P0-301199	Date: 30 11 1999
--      Version: MIB-P0-05092000 Date: 05 09 2000
--      Modification de la table des managers  
--
--		Name: S.LAURENT 	
--		Date: 25 04 2001 
--		Desc: * Add 7 equipment modification counters
--			   
--		Name: S.LAURENT 	
--		Date: 14 06 2002 
--		Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
--          
--		Name: F.Bonnevialle 	
--		Date: 15 11 2002 		
--		Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
--*******************************************************************




--*******************************************************************
-- MIB: EQUIPMENT-MIB
--*******************************************************************
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
 

--*******************************************************************
-- IMPORTS
--*******************************************************************

   IMPORTS
   sagemDr							FROM SAGEM-DR-MIB 
   MODULE-IDENTITY,
   		OBJECT-TYPE,
   		NOTIFICATION-TYPE,
		IpAddress,Counter32    		FROM SNMPv2-SMI
   DisplayString					FROM SNMPv2-TC;
--   TRAP-TYPE						FROM RFC-1215;
   



--*******************************************************************
-- OBJECTS
--*******************************************************************

--*******************************************************************

   equip	MODULE-IDENTITY
      LAST-UPDATED "0211150000Z"
      ORGANIZATION "SAGEM/DR Tolbiac Centre"
      CONTACT-INFO " "
      DESCRIPTION 
	"  
	Modification: 
			Date: 15 11 2002
			Description: 
			sagemDr replace sagem-dr
			NOTIFICATION-TYPE replace TRAP-TYPE
						
	Modification:
			Date: 14 06 2002
			Description: Modification of Imports
				DisplayString is imported from SNMPv2-TC instead of RFC1213				

	Modification:
			Date: 20 12 1999
			Description: Modification of comments
				Modification of bugs				
 
	Modification: 
			Date: 19 11 1999
			Name: sagem-dr, SagemBoolean
			Description: Definition of OID sagem-dr instead of sat      
				Definition of data SagemBoolean instead of Boolean 
	
			Name: communityString
			Description: SIZE(0..20) replaced by SIZE (0..50)


	New Object: 
			Date: 19 11 1999
		
			Name: All *Manager* are new objects
			Description: Manager list that recieves the traps.

			Name: equipCptModif
	 		Description: Incremental counter used to manage 
				the modifications	on the equipment.

	 		Name: communityAcces
	 		Description: new names used
				iONNOS-ANM-Supervisor instead of Set ...	

			Name: trapCommunity
			Description:SIZE(0..20) replaced by SIZE (0..50)

			Name: equipLoad
	 		Description: Object is simplified to an OID 
   
			Name: equipLoadDiagnostic
	 		Description: A string to help in case of problem  

			Name: transferedItemTable,transferedItem,
				TransferedItem,transferedItemIndex
				transferedItemType,transferedItemVersion
				transferedItemComments
	 		Description:
			These object are used to manage the download 
			and upload of some part of the data; the data
			can be a part of a program, a complete program,
			or a config.
			The transferedItemType is reused in equipLocalFile

	 		Name: equipStatusV2
			Description: used by IONOS ANM V2      

	"
      REVISION "9808040000Z"
      DESCRIPTION 
	"
	Creation : this MIB module describes equipment level operation such as
	date and time set, restart, reset, community and trap  
	management.
	"	
	      ::= { sagemDr 107 }

--*******************************************************************

SagemBoolean  ::= INTEGER { true(1), false(2) }
IntDateTime ::= INTEGER (0..2147483647) 
Severity    ::= INTEGER
      { 
		nonAlarmed (1), 
		minor (2), 
		major (3), 
		critical (4), 
		warning (5),
		invNonAlarmed (6),
		invMinor(7),
    	invMajor(8),
    	invCritical(9),
    	invWarning(10) 
	}


--*******************************************************************
   equipDateTime   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
      "The value of this field is the date and time of the equipment.
	It is the number of seconds since 1st January 1970."  
      ::= { equip 1 } 
   
   equipLastModif   OBJECT-TYPE
      SYNTAX       IntDateTime
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The date and time when the equipment was last modified."           
      ::= { equip 2 } 

   equipWarmStart   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The equipment make a hot start if this field is set to `true'.
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor. 
	The value returns to `false' after the restart."  
      ::= { equip 3 } 
   
   equipClearConf   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The equipment resets all its parameters, including those 
	stored in non-volatile media storage, if this field is set 
	to `true'.
	This command does not apply to mib-2 parameters, like @ip, 
	routing table, etc ...
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor. 
	The value returns to `false' after the reset.
	This operation is optionnal."  
      ::= { equip 4 } 
   
 
--*******************************************************************
-- Description:
--		Community 
--		 The "communityTable" is used for the habilitation.
--		It contains a sequense of "CommunityEntry" 
-- 		The size for the habilitation table is 10 elements for ADR equipement.
--		 A "CommunityEntry" is a sequence:
--		(communityIndex,communityString,communityAccess)
--		 The different kind of habilitation are:
--		iONOSANMobserver,
--		iONOSANMoperator,
--		iONOSANMsupervisor,
--		dIRECTACCESSobserver,
--		dIRECTACCESSoperator,
--		dIRECTACCESSsupervisor,
-- The 4 last one are used for the "Add Drop for IP" IPA.
--		iONOSANMclientobserver,
--		iONOSANMclientoperator,
--		dIRECTACCESSclientobserver,
--		dIRECTACCESSclientoperator.

   communityNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of community in equipment."  
      ::= { equip 5 } 
   
   communityTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF CommunityEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of community in equipment."  
      ::= { equip 6 } 
   
   communityEntry   OBJECT-TYPE
      SYNTAX       CommunityEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular community of the equipment." 
      INDEX        { communityIndex } 
      ::= { communityTable 1 } 

   CommunityEntry ::=
      SEQUENCE {
        communityIndex         INTEGER,
        communityString        DisplayString,
        communityAcces         INTEGER
      }
   
   communityIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular
	community."
      ::= { communityEntry 1 } 

 
  communityString   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A unique textual string that can be used by a SNMP manager as
	community string. It can be also used as password for other
	configuration like http, not only snmp.
	The table must have at least two entries associated with 
	the iONOSANMsupervisor access right (this entry is created by 
	equipement at startup with value `secret') and 
	dIRECTACCESSsupervisor access right (this entry is 	
	created by equipement	at startup  with value 'supervisor') . 
	According to equipment implementation, it is possible to 
	create other entries associed with lower rights that PDU 
	community string can afford (actualy equal if 
	IONOSANMsupervisor status is granted).
	If the other access rights are created at startup by the equipment,
	 its must use the following values : 'private' for 
	'iONOSANMoperator, 'public' for 'iONOSANMobserver', 
	 'operator' for dIRECTACCESSoperator, 'observer' for 
	dIRECTACCESSobserver, and 'client' for the others.
	
	All community string can be modified only by 
	IONOSANMsupervisor.
	A dIRECTACCESS community string can be modified by 
	dIRECTACCESSsupervisor.
	
	The reading of a community string gives *** for all 
	access rights .
	
	An entry may be discarded by setting its community string to 
	void string. This should not be used by the administrator or 
	he could discard himself "  

      ::= { communityEntry 2 }


   communityAcces   OBJECT-TYPE
      SYNTAX        INTEGER {iONOSANMobserver (1), 
                             iONOSANMoperator(2), 
                             iONOSANMsupervisor(3), 
				     		 dIRECTACCESSobserver (4),
                             dIRECTACCESSoperator(5), 
                             dIRECTACCESSsupervisor(6), 
                             iONOSANMclientobserver(7),
                             iONOSANMclientoperator(8),
                             dIRECTACCESSclientobserver(9),
                             dIRECTACCESSclientoperator(10)
				    }

      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"
	iONOSANMsupervisor(3) access :
		allows all operations including community string
		(community string = password)
	iONOSANMoperator(2) access :
		allows all set operations except write community
	   	string read or write and also some special operations.
	iONOSANMobserver (1) access : 
		allows only get and get_next requests.
	dIRECTACCESSsupervisor(6) access : 
		allows all operations EXcluding IONOS ANM community string
	dIRECTACCESSoperator(5) access :
		allows all set operations except write community
	   	string read or write and also some special operations.
	dIRECTACCESSobserver (4) access :
		allows only get and get_next requests.		
      iONOSANMclientoperator(8) access :                      
		allows only set some special operations 
      iONOSANMclientobserver(7) access :
		allows only get and get_next requests for special operations 
      dIRECTACCESSclientoperator(10) access :                      
		allows only set some special operations 
	dIRECTACCESSclientobserver(9) access :
		allows only get and get_next requests for special operations 
      "
     ::= { communityEntry 3 }    


--*******************************************************************
-- Description:
--		"trapTable": trap's receiver table  	

   trapNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of trap receivers description in equipment."  
      ::= { equip 7 } 
   
   trapTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF TrapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of trap receivers in equipment."  
      ::= { equip 8 } 
   
   trapEntry   OBJECT-TYPE
      SYNTAX       TrapEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular trap of the equipment." 
      INDEX        { trapIndex } 
      ::= { trapTable 1 } 
  
  TrapEntry ::=
      SEQUENCE {
	  trapIndex              INTEGER,
        trapDestination        IpAddress,
        trapCommunity          DisplayString
      }
   
  trapIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular
	trap receiver.
	The value of index is a constant assigned to an entry at
	equipment design time. "  
      ::= { trapEntry 1 } 
   
   trapDestination   OBJECT-TYPE
      SYNTAX       IpAddress
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The ip address to which the equipment will send the traps. 
	Note that the value must be unique along this table.
	An entry may be discarded by setting the IP address to 0.0.0.0
	" 
      ::= { trapEntry 2 } 
   
     
   trapCommunity   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
--	It is better to use a size value lower than 10.
--	The size value 50 is used for the BMX
	"The community string to use when a trap is sent to 
	this address. "  
      ::= { trapEntry 3 }    



--*******************************************************************

-- Description: 
--		Up and download for the software and configuration
-- 
   equipLoad   OBJECT IDENTIFIER ::= { equip 9 }
      
   equipLocalFile   OBJECT-TYPE
      SYNTAX       DisplayString       
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The file path suitable for the equipment."  
      ::= { equipLoad 1 } 
   
   equipServerAddress   OBJECT-TYPE
      SYNTAX       IpAddress
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The ip adress of tftp serveur from which is read/write 
	the file `equipRemoteFile'."  
      ::= { equipLoad 2 } 
   
   equipRemoteFile   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"The file path to be loaded on/from the equipement."  
      ::= { equipLoad 3 } 
   
   equipDirection   OBJECT-TYPE
      SYNTAX       INTEGER { download (0), upload(1)
			, backupDownload (2), switching (3)
	}
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"This field selects the direction of data stream.
	When it is set to `backupDownload', only the transfert is done.
	When it is set to `download' the transfert is done and then the 
	information transfert is switched in the operational state.
	When it is set to `switching', there is no transfert; 
	there is only  a switching. "     
      ::= { equipLoad 4 } 

   equipLoadProceed   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"
	This entry is use to start (set to `true') loading a file 
	on/from a equipment which has a tftp client.
	The value of the field remains to `true' until load is 
	completed or has been aborted.
	This operation can only be done by the iONOSANMsupervisor
	or dIRECTACCESSsupervisor.
	It may be possible to abort the loading by setting it 
	to false.
	After the switching of a new configuration, the equipment
	must increase the value of the variable 'equipCptModif' 
	"  
      ::= { equipLoad 5 } 
   
   equipLoadDiagnostic   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A string used to help in case of trouble."  
      ::= { equipLoad 6 }  
   
   equipLoadProtocole   OBJECT-TYPE
      SYNTAX       INTEGER { ftp (1), tftp (2), 
						http (3), telnet (4)}
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Protocole used by the equipment for the download"  
      ::= { equipLoad 7 }  


--*******************************************************************
-- Description: 
--		Delayed up and download for the software and configuration
--
--   equipLoadState   OBJECT-TYPE
--      SYNTAX       INTEGER { delayedLoad (1), loadRunning (2), 
--					delayedSwitching (3), switchingRunning (4),
--					loadOK (5), loadNOK (6) ,aborted (7)}
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"This field indicates the status of the current load processes valided 
--	by 'equipLoadProceed'.
--      Remark : a download includes a data transfer (load) from the 
--	server to the equipment and a switching for using the data or the 
--	software transfered . A upload includes only a data transfer from 
--	the equipment to the server
--	It's optional for the equipment which doesn't realise delayed download "
--	::= { equipLoad 8 } 
--
--	equipLoadDateTime   OBJECT-TYPE
--      SYNTAX       IntDateTime
--      MAX-ACCESS   read-write
--      STATUS       current
--      DESCRIPTION 
--      "The value of this field is the date and time of the equipment 
--	at which the load processes valided by 
--	'equipLoadProceed' must begin .
--	If this value if equal at 0 or < at the current
--	time, the load starts immediately.
--	It is the number of seconds since 1st January 1970."  
--	::= { equipLoad 9 }
--
--	equipSwitchingDateTime   OBJECT-TYPE
--      SYNTAX       IntDateTime
--      MAX-ACCESS   read-write
--      STATUS       current
--      DESCRIPTION 
--      "
--	The value of this field is the date and time of the equipment
--	at which the switching processes valided by 
--	'equipLoadProceed' must begin .If this value if equal at
--	0 or < at the current time, the switching starts immediately 
--	(if there isn't load)or immediately after the load (if there is a load).
--	It is the number of seconds since 1st January 1970.
--	After the switching of a new configuration, the equipment
--	must increase the value of the variable 'equipCptModif' 
--	"  
--	::= { equipLoad 10 } 
--


--*******************************************************************
-- Description:
--		These object are used to manage the download 
--		and upload of some part of the data; the data
--		can be a part of a program, a complete program,
--		or a config.
--			
--		The transferedItemType can be:
--			inactive programName 
--			active programName 
--			inactive"Config"
--			active"Config"
--			ALL Program
--			ALL
--
--		The transferedItemType is reused in equipLocalFile   


  transferedItemTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF TransferedItemEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of uploaded or downloaded Item from the 
	equipment."  
      ::= { equip 30 } 
   
   transferedItemEntry   OBJECT-TYPE
      SYNTAX       TransferedItemEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular Item transferd from/to the equipment." 
      INDEX        { transferedItemIndex } 
      ::= { transferedItemTable 1 } 

   TransferedItemEntry ::=
      SEQUENCE {
        transferedItemIndex         INTEGER,
        transferedItemType          DisplayString,
	  transferedItemVersion       DisplayString,
	  transferedItemComment       DisplayString  	
      }
   
   transferedItemIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	""  
      ::= { transferedItemEntry 1 } 
   
   transferedItemType   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"used to know what kind of data to transferate,
	mainly programName or config"
      ::= { transferedItemEntry 2 }

   transferedItemVersion   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"for a program, return the software version;
	for a config return the associated software version"
      ::= { transferedItemEntry 3 }

   transferedItemComment   OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"give additional information about the tranfered data"
      ::= { transferedItemEntry 4 }

--*******************************************************************
-- Description:

   equipStatus   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"This field summerizes the status of all equipment objects 
	(port, card, ...)
	This variable is polled by IONOS ANM V1
	The 'equipmentStatusTrap' is sent after a GET on this variable.
	equipStatus and equipStatusTrap are only used with V1. 
	"
      ::= { equip 10 } 

   equipStatusV2   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Replace equipStatus for the v2. For the v1, equipStatus 
	in EQUIPMENT-MIB send a trap after been polled; 
	For the v2, equipStatus is polled."  
      ::= { equip 11 } 

--*******************************************************************
--*   modification counters
--*******************************************************************
-- Description:
--		"equipCptModif":
--			Incremental counter used to manage the modifications
--			on the equipment.
-- Warning:
--		Replace equipLastModif for the new equipment ADR155c and 
--		the next generation of equipment. 

   equipCptModif   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter for all equipments modifications. It represents
        the sum of the 7 other counters"  
      ::= { equip 12 } 
 
   -- Modification counters
  cptModif	 		OBJECT IDENTIFIER ::= { equip 14 }
 
    cptSNC   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the SNC modifications."  
      ::= { cptModif 1 } 
     
      
    cptCnx   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Connexion modifications."  
      ::= { cptModif 2 } 
 
    cptMSP   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MSP modifications."  
      ::= { cptModif 3 } 

    cptMsSpring   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MS-SPRING modifications."  
      ::= { cptModif 4 } 

    cptSynchro   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Synchro modifications."  
      ::= { cptModif 5 } 

    cptMngt  OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the MNGT modifications (mngt list, password, trap, ...)."  
      ::= { cptModif 6 } 

    cptNet   OBJECT-TYPE
      SYNTAX       Counter32
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
        "The counter version for the Network modifications."  
      ::= { cptModif 7 } 
     

-- equipConfSaveStatus   OBJECT-TYPE
--      SYNTAX       SagemBoolean
--      MAX-ACCESS   read-only
--      STATUS       current
--      DESCRIPTION 
--	"If 'true', this variable indicates that all configuration
-- 	modifications are saved in flash memory. 
--	If false, this variable indicates that configuration 
--	modifications are not saved in flash memory. "  
--      ::= { equip 13 }


--*******************************************************************
--
-- Description:
-- 			ACCESS TABLE FILTER
--		The table is a access filter table that ckeck the IP address of 
--		the SNMP managers.


   equipManagerNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of manager = number of IP addresses in the table"  
      ::= { equip 20 } 

   equipManagerTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF EquipManagerEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	"Table containing Ip Addresses and maximum authorized level"
	::= { equip 21 }
	
   equipManagerEntry OBJECT-TYPE
	SYNTAX  EquipManagerEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	"Entry containing IP addresses of managers allowed in R/W."
	INDEX   {equipManagerIndex}
	::= {equipManagerTable 1}
	
   EquipManagerEntry ::=
	SEQUENCE        
		{
			equipManagerIndex INTEGER,        
			equipManagerAddress IpAddress,
			equipManagerADM SagemBoolean,
			equipManagerOPR SagemBoolean,
			equipManagerOBS SagemBoolean
		}
	
   equipManagerIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..2147483647) 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Index of equipManagerTable
	There's only 10 values in this table"
	::= {equipManagerEntry 1}
	
   equipManagerAddress OBJECT-TYPE
	SYNTAX  IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The IP address of one of the allowed managers.
   	If the table contains only address values which are equal
  	 to 0.0.0.0, no access filter are done.
   	Write the IP address 0.0.0.0 to remove a manager.
	This operation can only be done by the iONOSANMsupervisor.
	" 
	::= {equipManagerEntry 2}

   equipManagerADM   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have  the Supervisor rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 3}
 	
   equipManagerOPR   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have  the Operator rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 4}

  equipManagerOBS   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"If 'true', this variable indicates that the manager defined by 
	its address can have the Observer rigth as maximum level
	The value 'false' is set by the equipment when another level 
	is choosen"  
      ::= {equipManagerEntry 5}

--*******************************************************************
-- Warning: This Trap is only used for V1
--  equipStatusTrap  TRAP-TYPE
--   	ENTERPRISE  equip
--  	VARIABLES   { equipStatus }
--  	DESCRIPTION
--	"This trap indicates the alarm status of the equipment.
--	Only sent with IONOS ANM V1"
--      ::= 1
  
  equipTraps OBJECT IDENTIFIER ::= { equip 0 }
     
  equipStatusTrap NOTIFICATION-TYPE
          OBJECTS     { equipStatus }
          STATUS      current
          DESCRIPTION "This trap indicates the alarm status of the equipment.
						Only sent with IONOS ANM V1"
          REFERENCE   ""
          ::= { equipTraps 1 }
END